The content of this site has been prepared by the members of the thematic network "S2S - A Gateway for Plant and Process safety". Since the conditions of use are beyond our control we disclaim any liability, including patent infringement, incurred in connection with the use of these products, data or suggestions.

The thematic network S2S is a European Community Project carried out in the "Competitive and Sustainable Growth" programme and funded in part by contract number G1RT-CT-2002-05092.
 

Glossary

in
A B C D E F G H I J K L M N O P Q R S T U V W Z All terms
 

Vessel - 1 m?

The 1 m3 explosion vessel is a cylindrical vessel of 0,97 m I.D. and a length of 1,05 m, capable to withstand a maximum static overpressure of 20 bar. The front of the vessel is closed by a door, the rear by a blind flange. If necessary the blind flange can be replaced by other flanges to enable the testing of bursting disks, vent covers etc. The vessel is operated at room temperature. The 1 m3 explosion vessel is used to determine such explosion characteristics of flammable dust-air mixtures as maximum explosion overpressure, maximum rate of pressure rise or dust explosion constant Kst, lower explosion limit and minimum oxygen concentration for an explosion.

Reference:

  • TNO Prins Maurits Laboratory ? Explosion Prevention and Protection.
 