The content of this site has been prepared by the members of the thematic network "S2S - A Gateway for Plant and Process safety". Since the conditions of use are beyond our control we disclaim any liability, including patent infringement, incurred in connection with the use of these products, data or suggestions.

The thematic network S2S is a European Community Project carried out in the "Competitive and Sustainable Growth" programme and funded in part by contract number G1RT-CT-2002-05092.
 

Glossary

in
A B C D E F G H I J K L M N O P Q R S T U V W Z All terms
 

Quenching / Dumping

The potentially hazardous reaction is terminated by addition of a suitable component. The material can stop the reaction by dilution, lowering the temperature (e.g. with ice) or even through chemical inhibition.

Another possibility is an emergency transfer of the reaction mass to another tank containing e.g. water or a suitable solvent.

Reference:

  • ESCIS, Expert Commission for Safety in the Swiss Chemical Industry, Thermal Process Safety, Switzerland, 1993
 

Related Material


Contentbelongs to:Suppressant material
Contentbelongs to:Protection/Mitigation of runaway reactions
 